德国E+H数字电极电缆、不锈钢电磁流量计 |
|
点击次数:305 更新时间:2015-12-15 |
德国E+H数字电极电缆、不锈钢电磁流量计 品牌:德国E+H(德国Endress+Hauser集团) 产品描述 The Memosens data cable CYK10 withMemosens plug-head is usedtogether with the digital sensors withMemosens technology.An extension cable CYK81 and the junction box RM areavailable optionally. Your benefits: Absolute waterproof connection (ingress protection IP 68) No corrosion of contacts No influence of interfering potentials thanks to galvanic isolation of transmitter and medium 应用领域 The Memosens data cable CYK10 is applied in Memosens systems measuring the following parameters: pH/ORP Dissolved oxygen (amperometric) Conductive conductivity FMU40-4NB2C4 80F40-AD2SAADAABAA 80F50-AD2SAADAABAA 40E40-AD2SAADAAA 40E50-AD2SAADAAA FMU44-ATB2A22A FMU30-AAGEAAGGF PMC41-RE11M2J21T1 FTM51-AAF2L4A57AA L=340MM COM253-DX0005 COS41-2F CPS11D-7AA21 CPS12D-7PA21 PMC41-RE11H2C11M1 PMC41-RE11M2C11M1 FTM50-AGG2A4A12AA 53W4H-DR0B1AA0BAAN FMP40-1AA2CRJB21AAL=15000mm FTM50-AGJ2A4A52AA FTM50-ATD2A4A72AA TMR31-A1XBAAAC1AAA PMP46-RE17PBJCDGD CUM750-1E0AA CUS70-1A1A CPM223-MR00005 PMP131-A1B01A1R 德国E+H不锈钢电磁流量计 概述 常见使用故障 典型故障诊断及处理 1. 无流量输出。检查电源部分是否存在故障,测试电源电压是否正常;测试保险丝通断;检查传感器箭头是否与流体流向一致,如不一致调换传感器安装方向;检查传感器是否充满流体,如没有充满流体,更换管道或垂直安装。 2. 信号越来越小或突然下降。测试两电极间绝缘是否破坏或被短路,两电极间电阻值正常在(70~100)Ω之间;测量管内壁可能沉积污垢,应清洗和擦拭电极,切勿划伤内衬。测量管衬里是否破坏,如破坏应予以更换。 3. 零点不稳定,检查介质是否充满测量管及介质中是否存在气泡,如有气泡可在上游加装消气器,如水平安装可改成垂直安装;检查仪表接地是否完好,如不好,应进行三级接地(接地电阻≤100Ω);检查介质电导率应不小于5μs/cm;检查介质是否淤积于测量管中,清除时注意不要将内衬划伤。 4. 流量指示值与实际值不符。检查传感器中的流体是否充满管,有无气泡,如有气泡可在上游加装消气器;检查各接地情况是否良好;检查流量计上游是否有阀,如有,移至下游或使之全开;检查转换器量程设定是否正确,如不对,重新设定正确量程。 5. 示值在某一区间波动。检查环境条件是否发生变化,如出现新干扰源及其他影响仪表正常工作的磁源或震动等,应及时清除干扰或将流量计移位;检查测试信号电缆,用绝缘胶带进行端部处理,使导线、内屏蔽层、外屏蔽层、壳体之间不相互接触。 选用德国E+H不锈钢电磁流量计测量流量的流体必须是导电的,因此不导电的气体、蒸汽、油类、丙铜等物质不能选用德国E+H不锈钢电磁流量计测量流量。 运行期故障
|